The reference SFX power supply
Support standard SFX form factor and ATX via included bracket
300W continuous power output at 50 operating temperature rated for 24/7 operation
80 PLUS Bronze level efficiency (82%~85% efficiency at 20%~100% loading)
Class-leading single +12V rail with 22A
Intelligent semi-fanless operation
Silent running 80mm fan with 18dBA minimum
Single PCI-E 6pin connectors support
Active PFC
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - SST-ST30SF

SST-ST30SFThe reference SFX power supplySupport standard SFX form factor and ATX via included bracket300W continuous power output at 50℃ operating tem

Page 2 - Full Range Input

EPS 12V 8PIN connectorATX 12V 4PIN (4+4PIN EPS 12V in split mode) Signal Pin Pin Signal Black GND 1

Page 3

Warranty InformationWarranty terms & conditions1.Product component defects or damages resulted from defective production is covered under warranty

Page 4 - Measurements

April, 2013G11219230

Page 5

SFX Form Factor SST-ST30SF300W Switching Power Supply Active PFC Circuit Full Range Input1. GENERAL DESCRIPTION AND SCOPE2. REFER

Page 6

2.2. SAFETYCB: IEC 60950~1:2005(2nd Edition) and/or EN 60950~1:2006 +A11:2009UL: UL 60951-1 , 2nd Edition, 2007-03-27TUV: EN 60950-1:2006+All3.2. INRU

Page 7

3.4. EFFICIENCY3.4.1 GeneralUnder the load conditions defined in Table 1. and Table 2. The loading condition for testing efficiency shown in Table 1 r

Page 8 - 6. ENVIRONMENTAL REQUIREMENTS

4 . OUTPUT ELECTRICAL REQUIREMENTS4.1. OUTPUT VOLTAGE AND CURRENT RATING+3.3V 0.1A 10.5A 21A ±5%

Page 9 - 7. MECHANICAL REQUIREMENTS

4.3. HOLD-UP TIME (@Typical load of Table 1.)115V / 60Hz : 17 m sec. minimum. 230V / 50Hz : 17 m sec. minimum.The output voltage will remain within sp

Page 10

4.7. SHORT CIRCUIT PROTECTIONOutput short circuit is defined to be a short circuit load of less than 0.1 ohm.In the event of an output short circuit c

Page 11

4.9. The main power supply shall be off when the PS_ON pin is floating (open collector). The ON/STBY pin of P1 must remain off state for 5 Sec (maximu

Page 12 - G11219230

6.4. GROUND LEAKAGE CURRENTThe power supply ground leakage current shall be less than 3.5 mA.6.5. RELIABILITY6.6. DIELECTRIC STRENGTHThe power supply