SST-ST70F-ESBSST-ST60F-ESBSTRIDER ESSENTIAL SERIES High efficiency with 80 PLUS Bronze certification 24/7 continuous power output with 40℃ operating t
09SATA connectorSignal PinOrange +3.3V 5 Black COM 4 Red +5V 3 Black COM 2 Yellow +12V 1 Yellow BlackBlackRedSignal+12VCOMCOM+5VDCPin1234Pin1234Signa
STRIDER ESSENTIAL SERIES10Warranty InformationWarranty terms & conditions1.Product component defects or damages resulted from defective production
NO.G11220490
SPECIFICATIONSilverStone Strider EssentialST70F-ESBST60F-ESBATX12V 2.3 Switching Power SupplyWith Active PFC80Plus BronzePS/2011.1Scope1.GeneralThis s
STRIDER ESSENTIAL SERIES02* The power supply must operate at above frequency with 103.5 - 253VACrms input voltage range.2.3 Max. Input AC Current
03SST-ST60F-ESB:Output Voltage Load MINRange MAXPeak RegulationRipple & Noise P-P Max.1. +5V2. +3.3V3. +12V4. -12V5. +5Vs0.2A0.1A0.6A0.0A0
STRIDER ESSENTIAL SERIES04SST-ST70F-ESB:LoadLight LoadTypical LoadFull Load+5V2.83A7.06A14.13A+3.3V2.83A7.06A14.13A+12V9.47A23.68A47.35A-12V0.05A0.14A
053.8 3.3V Sense A default 3.3V sense line should be implemented pin 13 of the connector.3.9 Capacitive Load The power supply should be able to
STRIDER ESSENTIAL SERIES065. Start Stability5.1 No Load Start When power is applied to ST70F-ESB and ST60F-ESB with no load connected or unde
8.3 Insulation Resistance The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 minute.8.4 Dielectric Volt
STRIDER ESSENTIAL SERIES12.Power FactorThe power supply with active power factor correction, and meet the EN61000-3-2 standards, The power factor is g
Comments to this Manuals